Yamaha error codes
Yamaha PW-series mid-drive motors (PW-X3, PW-S2, PW-ST/TE/CE, PW-X2, PW-SE)
- 12 Display cannot talk to the drive unit medium
- 13 Display not compatible with drive unit medium
- 31 Torque sensor fault high
- 32 Torque sensor fault high
- 33 Torque sensor fault high
- 34 Torque sensor fault high
- 35 Torque sensor fault high
- 36 Torque sensor fault high
- 37 Torque sensor fault high
- 38 Crank sensor fault high
- 39 Crank sensor fault high
- 61 Controller fault high
- 63 Controller fault high
- 64 Controller fault high
- 66 Controller fault high
- 62 Motor fault high
- 67 Motor fault high
- 68 Encoder (motor position sensor) fault high
- 71 Battery fault high
- 73 Battery fault high
- 74 Battery fault high
- 79 DC/DC converter fault high
- SPD SNSR Speed sensor: check magnet medium
- IFX-SYSTEM Interface X: system problem (all lamps red) high
- IFX-BATTERY Interface X: battery problem (both indicators flash) high
- IFX-TURQUOISE Interface X: rightmost lamp flashes turquoise medium
- A:#### Automatic Support indicator flashing / 'A:####' shown medium
- ER 'Er'/'ER' alternating with the main display high
Systems and displays covered
- PW-SE / PW series SE – 2016+ drive unit
- PW-X / PW-X2 – eMTB drive units
- PW series TE / CE / ST – City/trekking drive units
- Display X – Small LCD display (PW-X)
- Display A – Larger LCD display
- Display C – Compact LCD display
- Interface X (X2Y) – LED switch/display for PW-X2/X3/ST/TE/CE